Computer room-1

Computer Room Air Handlers  

Anything But Traditional

Closeup 1-4 Closeup 2-3

Total Design Flexibility

Robust custom-engineering optimizes cooling capacity for any data center layout, from raised floors to slab designs.

Closeup 3-1 Closeup 4-1

Synonymous with Reliability

Our liquid-to-air heat transfer technology ensures better filtration coverage and higher heat exchange efficiency for less than 1% leakage.
Crah Dark default Crah Dark hover

Lower Energy Spend

Custom-engineered perimeter cooling that maximizes energy savings and minimizes air leakage.
circle image

Computer Room Air Handler (CRAH)

Unlike catalog units that force you to adapt to the equipment, our CRAHs are custom-built for mission-critical reliability within your specific facility constraints. Designed with our signature double-wall, fully sealed insulated panels and precision-balanced fans, these units provide superior thermal performance and quiet operation for the life of the data center.
CRAH_Angles_A_v01-edit
CRAH_Angles_B_v01-edit
CRAH_Angles_C_v01-edit
CRAH_Angles_D_v01-edit
CRAH_Angles_A_v01-edit
CRAH_Angles_B_v01-edit
CRAH_Angles_C_v01-edit
CRAH_Angles_D_v01-edit
Benefits & Features
CRAH_TabImage_A_v01-edit

Reliably Flexible

Our CRAH is precision-engineered to maintain peak performance, even as your footprint adapts. 

  • Total Design Flexibility – Designed to fit exact building dimensions, column layouts, and height restrictions that standard units can’t accommodate.
  • Superior Efficiency – Premium EC fans and optimum coil geometry minimize air pressure drops and reduce fan energy consumption.
  • Airtight Construction –Fully-sealed, double-wall insulated panels prevent air leakage and thermal loss, ensuring every watt is used for cooling.
  • Built for Longevity Fan assemblies are balanced to higher-than-industry standards, reducing vibration and extending bearing and motor life.
  • Integrated Monitoring –Available with advanced controls and full BMS integration to provide granular visibility into unit performance.
Technical Specifications

By the Numbers

Adaptable to the full spectrum of thermal demands, the CRAH enables precise cooling power for your specific density profile. High-capacity cooling and targeted airflow distribution provide the focused pressure and flow control necessary to eliminate specific hotspots and support diverse rack densities.

  • Cooling Capacity Range – 150 - 1000+ kW / 45 - 280+ Tons.
  • Airflow Range - Up to 100,000 CFM.
Industries Served

Unlock Ultimate Computing Power

Engineered for hyperscale and colocation facilities, our CRAH maximizes server space in any layout without sacrificing ambitious efficiency targets.

  • Enterprise Data Centers
  • Retrofit & Legacy System Upgrades
  • Server Rooms (Raised Floor or Flooded)

Need Cooling at Scale?

We design, engineer, and manufacture integrated data center cooling solutions that pave the way for AI-era growth, not hold it back.
Final-opt2-740x435
circle-bg-shape

In the News

Explore the latest news, updates, and insights shaping BASX and the industries we serve.
card 4-1
June 30, 2025
BASX Powers Advanced Cooling Innovation for Applied Digital’s Purpose-Built AI Data Center Campus
card 5-1
August 23, 2023
BASX Breaks Ground on a New Weld Shop
card 4-2
November 14, 2024
AAON Announces Expansion Plans to Increase Production Capacity With New Facility In Memphis
card 5-2
October 25, 2024
AAON Awarded Liquid Cooling Data Center Orders Totaling Approximately $174.5 Million